[TRANSLATION][INF] Update Chinese Traditional (zh-TW) translation (#3468)
[reactos.git] / media / inf / scsi.inf
1 ; SCSI.INF
2 ;
3 ; Installation file for SCSI class and SCSI hardware
4 ;
5 [Version]
6 Signature = "$Windows NT$"
7 ;Signature = "$ReactOS$"
8 LayoutFile = layout.inf
9 Class = SCSIAdapter
10 ClassGUID = {4D36E97B-E325-11CE-BFC1-08002BE10318}
11 Provider = %ReactOS%
12 DriverVer = 11/02/2007,1.1
13
14 [ClassInstall32.NT]
15 AddReg = SCSIClass.NT.AddReg
16
17 [SCSIClass.NT.AddReg]
18 HKR, , , 0, %SCSIClassName%
19 HKR, , Icon, 0, "-10"
20 ;HKR, , Installer32, 0, "syssetup.dll,ScsiClassInstaller"
21
22 [DestinationDirs]
23 DefaultDestDir = 12
24
25 [Manufacturer]
26 %GenericMfg% = GenericMfg
27
28 [GenericMfg]
29 %GEN_SCSIADAPTER.DeviceDesc% = NO_DRV,,GEN_SCSIADAPTER
30 %PCI\VEN_104B&CC_0100.DeviceDesc% = BusLogic_Inst,PCI\VEN_104B&CC_0100
31
32 ;----------------------------- ScsiPort Driver ----------------------------
33
34 [Scsiport_CopyFiles.NT]
35 scsiport.sys
36
37 [Scsiport_Service_Inst]
38 ServiceType = 4
39 StartType = 0
40 ErrorControl = 0
41 ServiceBinary = %12%\scsiport.sys
42 LoadOrderGroup = SCSI Port
43
44 ;---------------------------- NO DRIVER REQ -----------------------------
45
46 [NO_DRV]
47
48 [NO_DRV.Services]
49 AddService = , 0x00000002
50
51 ;----------------------------- BusLogic Driver ----------------------------
52
53 [BusLogic_Inst.NT]
54 CopyFiles = BusLogic_CopyFiles.NT, Scsiport_CopyFiles.NT
55
56 [BusLogic_CopyFiles.NT]
57 buslogic.sys
58
59 [BusLogic_Inst.NT.Services]
60 AddService = BusLogic, 0x00000002, BusLogic_Service_Inst
61 AddService = Scsiport, , Scsiport_Service_Inst
62
63 [BusLogic_Service_Inst]
64 ServiceType = 0
65 StartType = 0
66 ErrorControl = 0
67 ServiceBinary = %12%\buslogic.sys
68 LoadOrderGroup = SCSI Miniport
69
70 ;--------------------------------- Strings ---------------------------------
71
72 [Strings]
73 ReactOS = "ReactOS Team"
74 SCSIClassName = "SCSI and RAID Controllers"
75
76 GenericMfg = "(Standard SCSI and RAID controllers)"
77 GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID Host Controller"
78 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Controller"
79
80 [Strings.0404]
81 SCSIClassName = "SCSI / RAID 控制器"
82
83 GenericMfg = "(標準 SCSI / RAID 控制器)"
84 GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID 主機控制器"
85 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"
86
87 [Strings.0405]
88 SCSIClassName = "SCSI a RAID řadiče"
89
90 GenericMfg = "(Standardní SCSI a RAID řadiče)"
91 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI řadič"
92
93 [Strings.0407]
94 SCSIClassName = "SCSI und RAID Controller"
95
96 GenericMfg = "(Standard SCSI und RAID Controller)"
97
98 [Strings.0a]
99 ReactOS = "Equipo de ReactOS"
100 SCSIClassName = "Controladoras SCSI y RAID"
101
102 GenericMfg = "(Controladoras estándar SCSI y RAID)"
103 PCI\VEN_104B&CC_0100.DeviceDesc = "Controladora SCSI BusLogic"
104
105 [Strings.040C]
106 SCSIClassName = "Contrôleurs SCSI et RAID"
107
108 GenericMfg = "(Contrôleur standard SCSI et RAID)"
109
110 [Strings.0411]
111 SCSIClassName = "SCSIおよびRAID コントローラ"
112
113 GenericMfg = "(スタンダード SCSI および RAID コントローラ)"
114 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI コントローラ"
115
116 [Strings.0415]
117 ReactOS = "Zespół ReactOS"
118 SCSIClassName = "Kontrolery SCSI i RAID"
119 GenericMfg = "(Standardowe kontrolery SCSI i RAID)"
120 PCI\VEN_104B&CC_0100.DeviceDesc = "Kontroler SCSI BusLogic"
121
122 [Strings.0416]
123 SCSIClassName = "Controladores SCSI e RAID"
124
125 GenericMfg = "(Controladores SCSI e RAID padrão)"
126 PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
127
128 [Strings.0418]
129 ReactOS = "Echipa ReactOS"
130 SCSIClassName = "Dispozitive de control SCSI și RAID"
131 GenericMfg = "(dispozitiv standard de control SCSI și RAID)"
132 PCI\VEN_104B&CC_0100.DeviceDesc = "Dispozitiv de control SCSI BusLogic"
133
134 [Strings.0419]
135 ReactOS = "Команда ReactOS"
136 SCSIClassName = "SCSI и RAID контроллеры"
137
138 GenericMfg = "(Стандартные SCSI и RAID контроллеры)"
139 GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID хост-контроллер"
140 PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
141
142 [Strings.041B]
143 SCSIClassName = "SCSI a RAID radiče"
144
145 GenericMfg = "(Štandardné SCSI a RAID radiče)"
146 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI radič"
147
148 [Strings.041f]
149 ReactOS = "ReactOS Takımı"
150 SCSIClassName = "SCSI ve RAID Denetleyicileri"
151
152 GenericMfg = "(Ölçünlü SCSI ve RAID Denetleyicileri)"
153 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Denetleyicisi"
154
155 [Strings.0422]
156 ReactOS = "Команда ReactOS"
157 SCSIClassName = "SCSI і RAID контроллери"
158 GenericMfg = "(Стандартні SCSI і RAID контроллери)"
159 PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
160
161 [Strings.0427]
162 SCSIClassName = "SCSI ir RAID valdikliai"
163
164 GenericMfg = "(Standartiniai SCSI ir RAID valdikliai)"
165 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI valdiklis"
166
167 [Strings.0804]
168 GenericMfg = "(标准 SCSI / RAID 控制器)"
169 PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"